MPIO failure during reconfiguration request for target

$
0
0

Hello,

Recently we're receiving MPIO errors.

It starts with this error:

Subject: ASM: MPIO Page Table Download Error - iqn.2001-05.com.equallogic:0-8a0906-f70253d0b-8040000004f4e9bd-cq01  on host HYPER-V12

ASM from hyper-v12.pzmira.be at 05/06/2015 17:53:07 

[17:53:07] MPIO failure while downloading page table for target iqn.2001-05.com.equallogic:0-8a0906-f70253d0b-8040000004f4e9bd-cq01.

Followed by this error:

Subject: ASM: MPIO CHAP Creation Failure - iqn.2001-05.com.equallogic:0-8a0906-f70253d0b-8040000004f4e9bd-cq01  on host HYPER-V12

ASM from hyper-v12.pzmira.be at 05/06/2015 21:28:17 

[21:28:17] MPIO CHAP credential generation failed.

Then we get the following erro almost constantly:

Subject: ASM: MPIO Reconfiguration Request IPC Error - iqn.2001-05.com.equallogic:0-8a0906-c3c703c0b-bc0c79e1bce5472f-spdata  on host HYPER-V12

ASM from hyper-v12.pzmira.be at 05/06/2015 21:32:17 

[21:32:17] MPIO failure during reconfiguration request for target iqn.2001-05.com.equallogic:0-8a0906-c3c703c0b-bc0c79e1bce5472f-spdata with error status 0x80004005.

After getting these errors, I updated the firmware for the 2 Dell PS6000 SAN's we have to version 7.1.5.

This went well, but after about a week the errors came again. Probably because the SAN's were rebooted. We have 4 Dell R710-servers that are the host-server for our Hyper-v-cluster and all run Server 2008 R2 Datacenter. These servers are totally up-to-date and have the latest Qlogic network drivers installed.

We removed the Dell Auto Snapshot Manager-software because we actually don't use this, but it was installed from the beginning so I don't think the software is causing the problem. We use Acronis for backup. In de ASM-software I can disable the notifications for the above errors, which gave me a peaceful night-rest instead of receiving almost constantly an email :-)

But we removed the software, but now I can't disable the notifications, but still receive the notifications... Don't know where the mail is coming from then...

Unfortunately Dell Support is not helping me very much, although we have a support contract. They send me a pdf-file containing a guide for configuring the SAN's in a Hyper-V-environment.

The errors are not logged in the event viewer from the Hyper-V-server.

Changing the Quorum to another host-server will result in the same errors, but then it wil say "on host HYPER-V13" for example

I hope someone can clarify me, what the errors mean...