Is there a command to enable the HIT Kit to allow more than two MPIO connections?
I have a Windows Server with four dedicated iSCSI NICs, and the MPIO software from the HIT kit is not able to sustain more than two MPIO connections.
I can introduce a third and fourth session, but the MPIO software drops these connections after less than a minute.
Here's my configuration:
- Dell EqualLogic PS6500X (one member)
- Windows Server 2012 R2 iSCSI initiator
- HIT Kit version 4.7.
MPIO Configuration:
- MaxSessionsPerVolumeSlice : 4
- MaxSessionPerEntireVolume : 6
- DefaultLoadBalancing : 4
- DefaultLoadBalancingText : Least Queue Depth
- MinAdaptorSpeed : 1000
- UseMPIOForSnapshots : True
- UseIPv6 : False
MPIO Rule:
Type : Default Rule
SubnetMask :
Network :
Included : False
Type : MAC Address Rul
SubnetMask :
Network :
Included : False
Type : MAC Address Rul
SubnetMask :
Network :
Included : False
Type : Subnet Rule
SubnetMask : 10.10.240.0
Network : 255.255.255.0
Included : True
Type : Subnet Rule
SubnetMask : 169.254.0.0
Network : 255.255.0.0
Included : False
Type : Subnet Rule
SubnetMask : 10.21.60.0
Network : 255.255.255.0
Included : False
MPIO Adapter Configuration:
IPAddress Included
--------- --------
10.10.240.60 True
10.10.240.61 True
10.10.240.62 True
10.10.240.63 True